Details
In table below our range gassprings can be found with the most important values and formulas stated.
To find out more details please click the type in the table. You will be redirected to a new page. (UNDER CONSTRUCTION)
Endfittings and brackets can be found in the both specific sections.
NOTE: the extended length EL1 can be calculated with the length EL2 added with the length of both choosen endfittings!
Type øx/øy |
Stroke A in mm min-max |
Minimum length EL2 extended |
Progression |
Force (N) min-max |
3/8 | 10-120 | Stroke x 2 + 20 | ca. 28% | 10-110 |
4/12 | 10-150 | Stroke x 2 + 30 | ca. 21% | 10-200 |
6/15 | 10-150 | Stroke x 2 + 33 | ca. 27% | 25-400 |
8/18 | 10-300 | Stroke x 2 + 42 | ca. 33% | 50-750 |
8/21 | 10-300 | Stroke x 2 + 44 | ca. 22% | 50-750 |
10/21 | 20-500 | Stroke x 2 + 44 | ca. 39% | 100-1300 |
10/27 | 20-500 | Stroke x 2 + 54 | ca. 21% | 100-1300 |
14/27 | 20-1000 | Stroke x 2 + 54 | ca. 52% | 150-2600 |
14/40 | 20-1000 | Stroke x 2 + 70 | ca. 18% | 150-2600 |
20/40 | 20-1000 | Stroke x 2 + 90 | ca. 45% | 200-5000 |